VA700 Calibrator for 4-20mA current loops, 0-5Vdc, and 0-10Vdc
Measures, outputs and displays several of the common industry signal standards. Suitable for working on 4-20mA, 0-5Vdc, 0-10Vdc (reversing can give you ±-0-10Vdc)
SPECIFICATIONS |
Function |
Range |
Accuracy |
Resolution |
DCV mV Input |
0-100 mV |
0.02% + 2 |
0.01 mV |
0-10 V |
0.001V |
DCV mV output |
0-100 mV |
0.01 mV |
0-10 V |
0.001 V |
Loop Power Output |
24 VDC |
±10%+2 |
N/A |
DC mA input |
0-24 mA |
0.015% + 2 |
0.001 mA |
DC mA output |
0-24 mA |
More about Standard Industrial Signals
- Input Impedance: 2M (nominal), < 100pF
- Over Voltage protection: 30 V
- Voltage Driver Capability: 1 mA
- Overload Protection: 125 mA, 250V fast acting fuse
- Current Percent Display: 0%=4mA, 100%=20mA
Physical Characteristics
- Storage temperature: - 40 °C - 60 °C
- Operating temperature: - 10 °C - 55 °C
- LCD size: 64 X 42 mm
- Power source: AAA 1.5V X 6
- Dimensions: 204 X 99 X 46 mm
- Weight: 460 grams
What's in the box
- V&A VA700 Calibrator
- Test leads
- AAA battery: 6
- User manual
Index 32997 1.000