MS8209 5 in 1 Meter: Sound Level, Brightness (Lux), Thermometer, Humidity Meter, Multimeter
Specifications of the MS8209 5 in 1 meter |
As a multimeter |
DC Voltage |
Range |
Resolution |
Accuracy |
400mV |
0.1mV |
± (0.7% of
reading + 2 digits) |
4V |
1mV |
± (0.7% of
reading + 2 digits) |
40V |
10mV |
± (0.7% of
reading + 2 digits) |
400V |
100mV |
±(0.7% of
reading + 2 digits) |
600V |
1V |
± (0.7% of reading + 2 digits) |
Input impedance: 10 M Ohm |
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage :
600V DC or rms AC |
AC Voltage |
Range |
Resolution |
Accuracy |
4V |
1mV |
±
|
40V |
10mV |
±(0.8% of reading + 3digits) |
400V |
100mV |
± (0.8% of reading + 3 digits) |
600V |
1V |
± (0.8% of reading + 3 digits) |
Input impedance: 10 MOhm |
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage :
600V DC or rms AC |
Frequency range: 40 to 1000Hz, |
Response: Average, calibrated in
rms of sine wave. |
|
DC Current |
Range |
Resolution |
Accuracy |
40mA |
10uA |
±
(1.2% of reading + 3 digits) |
400mA |
100uA |
10A |
10mA |
± (3.0% of
reading + 10 digits) |
mA ranges: F500mA/250V fuse (quick
acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack
:10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A |
|
AC Current |
Range |
Resolution |
Accuracy |
40mA |
10uA |
±
(1.5% of reading + 5 digits) |
400mA |
100uA |
10A |
10mA |
± (3.0% of
reading + 10 digits) |
mA ranges: F500mA/250V fuse (quick
acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack
:10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A |
Response: Average, calibrated in rms
of sine wave. |
|
Resistance |
Range |
Resolution |
Accuracy |
400 >Ω |
0.1>Ω |
±
(1.2% of reading + 2 digits) |
>4KΩ |
1>Ω |
40K>Ω |
10>Ω |
400K>Ω |
100>Ω |
4M>Ω |
1K>Ω |
40M>Ω |
10>Ω |
±(1.2% of reading + 2 digits) |
Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC |
Capacitance |
Range |
Resolution |
Accuracy |
4nF |
1pF |
±
(3.0% of reading + 3 digits) |
40nF |
10pF |
400nF |
0.1nF |
4uF |
1nF |
40uF |
10nF |
200uF |
100nF |
Overload Protection: 250V DC or rms
AC |
|
Frequency |
Range |
Resolution |
Accuracy |
9.999 Hz |
0.001Hz |
± (2.0% of
reading + 5 digits) |
99.99Hz |
0.01 Hz |
±
(1.5% of reading + 5 digits) |
999.9 Hz |
0.1Hz |
9.999 KHz |
1 Hz |
99.99 KHz |
10 Hz |
±
(2.0% of reading + 5 digits) |
199.9 KHz |
100 Hz |
>200 KHz |
. |
Reference only |
By Hz Range:
Range: 0 - 200 KHz
Input Voltage: 0.5V - 10V rms
AC
By V Range:
Range: 0 - 40 KHz
Input Voltage range: 0.5V -
600V rms AC, Input impedance: 10M>Ω
>By mA Range:
>Range: 0 -40
KHz, Input current range: 100mA- 400mA rms AC |
Duty Cycle |
Range |
Resolution |
Accuracy |
0.1 - 99.9 % |
0.1% |
± 3.0% |
Note: When measuring frequency, the range by Duty of Hz range is
larger than by Duty of voltage ot current range. More to see on the manual book. |
Diode |
Range |
Resolution |
Accuracy |
Diode drop |
1mV |
Display: read appromix forward
voltage of diode |
Continuity |
Built in buzzer
will sound if the resistance is lower than 40 Ohms. |
As a Thermometer |
Range |
Resolution |
Accuracy |
0.1>°C |
>0.1°C |
-20>° to 0 ° |
± (5.0% of reading + 8
digits) |
0>°C to 20 °C |
±(3.0% of reading + 8
digits) |
20 >°C to 400°C |
± (2.0% of reading + 5
digits) |
>0.1°C |
1 >°C |
-20>°C to 0°C |
±(5.0% of reading + 5
digits) |
0>°C to 400°C |
±(1.0% of reading + 3
digits) |
400>°C to 1000°C |
±(2.0% of reading + 3
digits) |
|
As a Humidity Meter |
Range |
Resolution |
Accuracy |
30 - 90 % |
0.1% |
± 5.0% RH |
Response time: 45% - 90 %RH < 10
Minutes, 90% - 45% < 15 Minutes |
As a Sound Level Meter |
Range |
Resolution |
Accuracy |
30dB - 100dB |
0.1dB |
± 3.5% dB at 94 dB, 1K Hz sine wave. |
|
|
|
Range |
Resolution |
Accuracy |
Lux ( 4000) |
1 Lux |
± (5.0% of
reading + 10 digits) at color temp. 2850K, calibrated to standard
incandescent lamp at color temperature 2856 K |
X 10 Lux ( 40000) |
10 Lux |