MS8209 New


Brand: ROC
ROC
$79.95 USD

MS8209 5 in 1 Meter: Sound Level, Brightness (Lux), Thermometer, Humidity Meter, Multimeter
  • DCV: 0/400mV/4V/40V/400V/600V ± 0.7%
  • ACV: 0V/4V/40V/400V/60V - ±1.0% (True RMS)
  • DCA: 40mA/400mA/10A ±0.5%
  • ACA: 40mA/400mA/10A ±1.5%
  • Ohm: 400/4K/40K/400K/4M/40M ±1.2%
  • Capacitance: 4nF/40nF/400nF/4uF/40uF/200uF
  • Frequency: 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/1 99.9KHz-200KHz ± 0.5%
  • Duty Cycle: 0.1 -99.9% ±3.0%
  • Temp: -20 °C -  1000 °C ± 1.0% ( Two Ranges)
  • Humidity (RH):30 - 90 %
  • Sound Level: 35 - 100 dB (0.1dB/3.5%)
  • Luminance : Lux (4,000) - 10X Lux(40,000) 5.0%
  • Audible Continuity test with Diodes test.
  • Data Hold
  • Function Transform: DC/AC selectable
  • Range Transform: Auto ranging and manual ranging selectable.
  • HZ/DUTY Transform
  • Relative Transform: You can zero the meter by pushing relative button.
  • Back Light: Beautiful neon style back light makes measurement  possible in darkness.
  • Auto Power off: In 15 minutes, the meter will auto power off with 5 short buzz and one long warning buzz.
  • Back Stand up Holder
  • Nylon carrying pouch, 9V battery
Specifications of the MS8209 5 in 1 meter
As a multimeter
DC Voltage
Range Resolution Accuracy
400mV 0.1mV ± (0.7% of reading + 2 digits)
4V 1mV ± (0.7% of reading + 2 digits)
40V 10mV ± (0.7% of reading + 2 digits)
400V 100mV ±(0.7% of reading + 2 digits)
600V 1V ± (0.7% of reading + 2 digits)
Input impedance: 10 M Ohm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC
AC Voltage
Range Resolution Accuracy
4V 1mV ±
40V 10mV ±(0.8% of reading + 3digits)
400V 100mV ± (0.8% of reading + 3 digits)
600V 1V ± (0.8% of reading + 3 digits)
Input impedance: 10 MOhm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC
Frequency range: 40 to 1000Hz,
Response: Average, calibrated in rms of sine wave.
DC Current
Range Resolution Accuracy
40mA 10uA ± (1.2% of reading + 3 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A
AC Current
Range Resolution Accuracy
40mA 10uA ± (1.5% of reading + 5 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A
Response: Average, calibrated in rms of sine wave.
Resistance
Range Resolution Accuracy
400 >Ω 0.1>Ω ± (1.2% of reading + 2 digits)
>4KΩ 1>Ω
40K>Ω 10>Ω
400K>Ω 100>Ω
4M>Ω 1K>Ω
40M>Ω 10>Ω ±(1.2% of reading + 2 digits)
Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC
Capacitance
Range Resolution Accuracy
4nF 1pF ± (3.0% of reading + 3 digits)
40nF 10pF
400nF 0.1nF
4uF 1nF
40uF 10nF
200uF 100nF
Overload Protection: 250V DC or rms AC
Frequency
Range Resolution Accuracy
9.999 Hz 0.001Hz ± (2.0% of reading + 5 digits)
99.99Hz 0.01 Hz ± (1.5% of reading + 5 digits)
999.9 Hz 0.1Hz
9.999 KHz 1 Hz
99.99 KHz 10 Hz ± (2.0% of reading + 5 digits)
199.9 KHz 100 Hz
>200 KHz . Reference only
By Hz Range: Range: 0 - 200 KHz

Input Voltage: 0.5V - 10V rms AC

By V Range:

Range: 0 - 40 KHz

Input Voltage range: 0.5V - 600V rms AC, Input impedance: 10M>Ω

>By mA Range:

>Range: 0 -40 KHz, Input current range: 100mA- 400mA rms AC
Duty Cycle
Range Resolution Accuracy
0.1 - 99.9 % 0.1% ± 3.0%
Note: When measuring frequency, the range by Duty of Hz range is larger than by Duty of voltage ot current range. More to see on the manual book.
Diode
Range Resolution Accuracy
Diode drop 1mV Display: read appromix forward voltage of diode
Continuity
Built in buzzer will sound if the resistance is lower than 40 Ohms.
As a Thermometer
Range Resolution Accuracy
0.1>°C

>0.1°C

-20>° to 0 ° ± (5.0% of reading + 8 digits)
0>°C to 20 °C ±(3.0% of reading + 8 digits)
20 >°C to 400°C ± (2.0% of reading + 5 digits)
>0.1°C 1 >°C -20>°C to 0°C ±(5.0% of reading + 5 digits)
0>°C to 400°C ±(1.0% of reading + 3 digits)
400>°C to 1000°C ±(2.0% of reading + 3 digits)
As a Humidity Meter
Range Resolution Accuracy
30 - 90 % 0.1% ± 5.0% RH
Response time: 45% - 90 %RH < 10 Minutes, 90% - 45% < 15 Minutes
As a Sound Level Meter
Range Resolution Accuracy
30dB - 100dB 0.1dB ± 3.5% dB at 94 dB, 1K Hz sine wave.
Range Resolution Accuracy
Lux ( 4000) 1 Lux ± (5.0% of reading + 10 digits) at color temp. 2850K, calibrated to standard incandescent lamp at color temperature 2856 K
X 10 Lux ( 40000) 10 Lux
Reviews
Index 1 1.000


DC UPS System
DC UPS System →
Toshiba PLCs
Toshiba PLCs →
Test Equipment
Test Equipment →
Panel Meters
Panel Meters →
Universal Programmer
Universal Programmer →
EPROM Programmer
EPROM Programmer →
Power Supplies
Power Supplies →
EPROM Emulator
EPROM Emulator →
Optivisor
Optivisor →
Floobydust
Floobydust →
Information
Support
Site Map
Contact Us
Privacy Notice
Design Services
Shipping & Returns