OPTO-TRIAC Logic level converter and isolator - Connects 5 - 24Vdc to 120Vac PLC inputs
Opto-isolation prevents ground current problems
Specifications |
Isolation | 7500 Vav(pk) 5000 Vrms |
Min Input drive current required | 0.7mA |
Min input voltage level | 2.7Vdc OPTO-Triac |
Maximum input voltage | 25Vdc OPTO-Triac |
Min output current delivered | 300 mA |
Maximum output voltage | 50V |
Maximum output current | 150mA |
Maximum Frequency (50% duty cycle) | 10Khz |
Opto120AC | Halfwave detection (may require pulse stretching in ladder software) |
Index 33000 0.050