Transtronics, Inc My Account            Cart Contents            Checkout  
  Top » Catalog » Test Equipment » My Account  |  Cart Contents  |  Checkout   
Shopping Cart more
1 x C2400
1 x IL-AG5-7S-S3C1
1 x TDR116S6S
1 x PD6000-7R7
1 x GM-U5
$857.19
Categories
Toshiba PLCs (248)
Motor Protectors (3)
Panel Meters (95)
Test Equipment (15)
EPROM Programmer (107)
EPROM Emulator (7)
Power Supplies (25)
DC UPS System (7)
Optivisor (33)
Humidity-Temp logger (4)
Tower-Lighting Alarm Monitor (4)
Floobydust (50)
Newest Products
Go to..
What's New? more
OIS60
OIS60
$949.00
Search
 
Use keywords to find the product you are looking for.
Advanced Search
ShoppingCart Map
Information
Shipping & Returns
Privacy Notice
Conditions of Use
Contact Us
Payments Accepted


SSL CERTIFICATE

MS8209 $79.95
Reviews

MS8209
Click to enlarge

MS8209
Click to enlarge

MS8209 5 in 1 Meter: Sound Level, Brightness (Lux), Thermometer, Humidity Meter, Multimeter

  • DCV: 0/400mV/4V/40V/400V/600V ± 0.7%
  • ACV: 0V/4V/40V/400V/60V - ±1.0% (True RMS)
  • DCA: 40mA/400mA/10A ±0.5%
  • ACA: 40mA/400mA/10A ±1.5%
  • Ohm: 400/4K/40K/400K/4M/40M ±1.2%
  • Capacitance: 4nF/40nF/400nF/4uF/40uF/200uF
  • Frequency: 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/1 99.9KHz-200KHz ± 0.5%
  • Duty Cycle: 0.1 -99.9% ±3.0%
  • Temp: -20 °C -  1000 °C ± 1.0% ( Two Ranges)
  • Humidity (RH):30 - 90 %
  • Sound Level: 35 - 100 dB (0.1dB/3.5%)
  • Luminance : Lux (4,000) - 10X Lux(40,000) 5.0%
  • Audible Continuity test with Diodes test.
  • Data Hold
  • Function Transform: DC/AC selectable
  • Range Transform: Auto ranging and manual ranging selectable.
  • HZ/DUTY Transform
  • Relative Transform: You can zero the meter by pushing relative button.
  • Back Light: Beautiful neon style back light makes measurement  possible in darkness.
  • Auto Power off: In 15 minutes, the meter will auto power off with 5 short buzz and one long warning buzz.
  • Back Stand up Holder
  • Nylon carrying pouch, 9V battery
± 3.5% dB at 94 dB, 1K Hz sine wave.
Specifications of the MS8209 5 in 1 meter
As a multimeter
DC Voltage
Range Resolution Accuracy
400mV 0.1mV ± (0.7% of reading + 2 digits)
4V 1mV ± (0.7% of reading + 2 digits)
40V 10mV ± (0.7% of reading + 2 digits)
400V 100mV ±(0.7% of reading + 2 digits)
600V 1V ± (0.7% of reading + 2 digits)
Input impedance: 10 M Ohm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC
AC Voltage
Range Resolution Accuracy
4V 1mV ±
40V 10mV ±(0.8% of reading + 3digits)
400V 100mV ± (0.8% of reading + 3 digits)
600V 1V ± (0.8% of reading + 3 digits)
Input impedance: 10 MOhm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC
Frequency range: 40 to 1000Hz,
Response: Average, calibrated in rms of sine wave.
DC Current
Range Resolution Accuracy
40mA 10uA ± (1.2% of reading + 3 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A
AC Current
Range Resolution Accuracy
40mA 10uA ± (1.5% of reading + 5 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A
Response: Average, calibrated in rms of sine wave.
Resistance
Range Resolution Accuracy
400 >Ω 0.1>Ω ± (1.2% of reading + 2 digits)
>4KΩ 1>Ω
40K>Ω 10>Ω
400K>Ω 100>Ω
4M>Ω 1K>Ω
40M>Ω 10>Ω ±(1.2% of reading + 2 digits)
Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC
Capacitance
Range Resolution Accuracy
4nF 1pF ± (3.0% of reading + 3 digits)
40nF 10pF
400nF 0.1nF
4uF 1nF
40uF 10nF
200uF 100nF
Overload Protection: 250V DC or rms AC
Frequency
Range Resolution Accuracy
9.999 Hz 0.001Hz ± (2.0% of reading + 5 digits)
99.99Hz 0.01 Hz ± (1.5% of reading + 5 digits)
999.9 Hz 0.1Hz
9.999 KHz 1 Hz
99.99 KHz 10 Hz ± (2.0% of reading + 5 digits)
199.9 KHz 100 Hz
>200 KHz Reference only
By Hz Range: Range: 0 - 200 KHz

Input Voltage: 0.5V - 10V rms AC

By V Range:

Range: 0 - 40 KHz

Input Voltage range: 0.5V - 600V rms AC, Input impedance: 10M>Ω

>By mA Range:

>Range: 0 -40 KHz, Input current range: 100mA- 400mA rms AC
Duty Cycle
Range Resolution Accuracy
0.1 - 99.9 % 0.1% ± 3.0%
Note: When measuring frequency, the range by Duty of Hz range is larger than by Duty of voltage ot current range. More to see on the manual book.
Diode
Range Resolution Accuracy
Diode 1mV Display: read appromix forward voltage of diode
Continuity
Built in buzzer will sound if the resistance is lower than 40 Ohms.
As a Thermometer
Range Resolution Accuracy
0.1>°C

 

>0.1°C

 

-20>° to 0 ° ± (5.0% of reading + 8 digits)
0>°C to 20 °C ±(3.0% of reading + 8 digits)
20 >°C to 400°C ± (2.0% of reading + 5 digits)
>0.1°C 1 >°C -20>°C to 0°C ±(5.0% of reading + 5 digits)
0>°C to 400°C ±(1.0% of reading + 3 digits)
400>°C to 1000°C ±(2.0% of reading + 3 digits)
As a Humidity Meter
Range Resolution Accuracy
30 - 90 % 0.1% ± 5.0% RH
Response time: 45% - 90 %RH < 10 Minutes, 90% - 45% < 15 Minutes
As a Sound Level Meter
Range Resolution Accuracy
30dB - 100dB 0.1dB
Lux Meter
Range Resolution Accuracy
Lux ( 4000) 1 Lux ± (5.0% of reading + 10 digits) at color temp. 2850K, calibrated to standard incandescent lamp at color temperature 2856 K
X 10 Lux ( 40000) 10 Lux

Reviews
Product Link MS8209
index 33000-1.65
Transtronics, Inc.
3209 W.9th street
Lawrence, KS 66049
USA
 
Ph
FAX
Email
WEB
Cart map
+1(785) 841 3089
+1(785) 841 0434
inform@xtronics.com
http://xtronics.com
http://secure.transtronics.com

Corporate Home Page
(C) Copyright 1994-2009, Transtronics, Inc. All rights reserved
Transtronics® is a registered trademark of Transtronics, Inc.
All trademarks are the property of their respective owners.