MAP-40-3100
Triple output 40Watt Power supply +5V @ 3A, +12V @ 2A and -12 @ 0.3A
Nice UL, CSA, and TUV approved supply.
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. MAP42 85 264 VAC
MAP30, MAP40 90 264
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with
full rated loads. 85 VAC
Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 mS
Input Current 90 VAC (40W load). 1.2 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle).
25° C. 38 APK
Operating Frequency Switching frequency of power supply (fixed frequency). 23 25
30 kHz
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load, 120VAC. 70 %
Minimum Loads Single output models; MAP30, MAP42. 0.0 Amps
All multiple output models, see regulation graphs.
Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart.
Output Power Multiple output models with convection cooling. 40 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 %
Regulation Varies by output, total regulation includes: Line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing See regulation
graphs.
to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a
50-100% 500 m S
load change, 4% max. deviation. (Main output only of multiple output units).
Turn-on Delay Time required for initial output voltage stabilization. 1 2 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
MAP30-1005, MAP42-1005 5.8 6.8
Overvoltage MAP42-1012 20.0 22.0 V
Protection MAP42-1024 32.0 37.0
Main output only of multiple output units. 5.8 6.8
Overload Fully protected against output overload and short circuit. Automatic
130 %
Protection recovery upon removal of overload condition.
Remote Sense Total cable drop, single output models only. 250 mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL1950.
CSA 22.2 No. 234/950. Approved.
EN60950 (TUV).
Dielectric Withstand Input to output. 2600 VDC
Voltage
Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted. B
Interference EN55022 / CISPR 22 conducted (Note 1). B Class
EN55022 / CISPR 22 radiated (Note 2). B
Input Transient EN61000-4-5 Level 3 Line to Line 1 kV
Protection Line to Ground 2
Insulation Resistance Input to output. 7 MW
Leakage Current Per EN60950, 264VAC MAP42, MAP40-3100, 3001, 3105, 3500 500
m A
MAP30-1005, MAP40-3000, MAP40-3003 750
NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A.
2) MAP40-3000, MAP40-3003, MAP3500 meet Class A.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating. 10k ASL Ft.
Non-operating. 40k ASL Ft.
Operating Temperature Derate linearly above 50°C by 2.5% At 100% load: 0 50 °C
per °C to a maximum temperature of 70°C. At 50% load: 0 70 °C
Storage Temperature -40 85 °C
Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.03
%/°C
Relative Humidity Non-condensing. 5 95 %RH
Shock Operating, peak acceleration. 20 G
Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 GRMS
MAP30/40/42 SERIES
Full specifications in
a PDF
OUTPUT
VOLTAGE |
ADJUSTMENT
RANGE |
OUTPUT
CURRENT |
PEAK OUTPUT
CURRENT (NOTE 1) |
LINE
REGULATION |
LOAD |
RIPPLE & NOISE
REGULATION %p-p (NOTE 2) |
INITIAL SETTING
ACCURACY |
| +5V |
4.75V to 5.25V |
3A |
5A |
0.2% |
2% |
1% |
4.9V to 5.1V |
| +12V |
Fixed |
2A |
3.5A |
1% |
3.5% |
(Note 3) 1% |
11.5V to 12.5V |
| -12V |
Fixed |
0.3A |
0.5A |
1% |
2% |
1% |
-11.4V to -12.6V |
NOTES :
1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz
bandwidth.
3) Quasi regulated output. See Regulation Curves for more information.
4) Requires a minimum load of 0.5A on V1 or 0.3A on V2.
|