OIS15 4 Line by 16 character backlit LCD, 8 Operator Keys 4 LEDs, NO
PROGRAMMING-Messages & Functions are stored in PLC, Power from PLC.
Comes with cable for T1.
The OIS15 displays 4 lines of up to 16 characters per line. The number of
different displays (messages, etc.) is limited only by the available PLC memory
(program memory, register memory, or a combination of both).
Displays can be:
- Messages based on any PLC condition
- Alarms flashing OFF and ON
- Embedded register values
- Variable bar graphs
- Text (such as PV, MV, SV, etc.) can also be embedded in the bar
graph
FUNCTION KEYS
The OIS15 has 8 user definable function keys. These keys can be used as push-buttons or as toggle
switches. Keys can do the following functions:
- Enter a value into a specified register
- Control a multiple selection menu
- Alarm/Message Display
(with embedded variables)
- Multiple Bar Graph Display
- Pushbuttons
- Function Keys Set
- Register Values
- Function Keys Adjust
Timer & Counter Presets
ANNUNCIATOR LEDs
The OIS15 has 4 user definable LEDs.
Each LED can be turned ON or OFF when a designated coil or bit in
the PLC is ON or OFF. Each designated LED can also be turned ON when one of the
following occurs: A register value is less than, equal to, or greater than a
specified limit.
Again, note that all operations described above are dependent on the
PLC ladder logic program. The OIS10 use the PLCs programming.
No new Programming environment to learn
No Wiring: Simply plug the cable into the PLC RS232 programming
port. No other connections are necessary. The OIS is powered from the PLC.
No Programming: These OISs do not require a program. All messages
and other actions are stored in PLC program or register memory. Now all that
extra register memory and the ASCII conversion instruction in the T1 PLCs can
be used. Over 999 data registers are available for storing ASCII messages in
standard T1s. 4,000 plus registers are available in the Super T1-40 and T2E
PLCs. And 8,000 plus registers are available in the T2N.
The OIS operation is controlled by the status of pre-assigned
registers in the PLC.
Toshiba PLCs! They have lots of Memory!
- If program memory is limited (which it usually isn't) ASCII
characters can be stored directly in the data register memory using the
ASCII entry mode in the Data Monitor View. This method eliminates all
the ASC (ASCII) progam instructions in the example above.
- For additional information, please refer to the OIS Quick Start.
Notes:
If you are using a T1 with a RS485 controller you can plug the OIS
into the programming port and program the T1 via the RS485. In the Programming
software, select connect via computer link - 485. The other way is to use an AB
serial switch.
| OIS15 |
| |
OIS10: 2 Line x 16 Character Backlit LCD. |
| Display: |
OIS16: 4 Line x 16 Character Backlit LCD. |
| |
IP 65 rated Keypad |
| Display Rating: |
OIS10: 6 User Assignable Function Keys. |
| Keys |
OIS15: 8 User Assignable Function Keys. |
| |
OIS10: 2 (1 Red & 1 Green) |
| LEDs |
OIS15: 4 Red. |
| Panel Cutout: |
OIS10: 92 mm x 45 mm. (1/8 DIN). |
| OIS15: 92 mm x 92 mm (1/4 DIN). |
| Communication Ports: |
One port connects to the PLC. |
| Certifications: |
CE, UCSA |
| Power: |
5 Vdc + 5%, 120 mA from PLC Port. |
| Weight: |
OIS10: 140 g. OIS15: 240 g. |
|