$84.95

BVUPS12
[BVUPS]

Product Link BVUPS12

Transtronics Battery Voltage UPS™ (BVUPS™)
12V version

New! Compatible Din Rail power supplies!

The Transtronics BVUPS™ protects your investment in batteries and increases system reliability

  • Are your lead-acid batteries prematurely dying a deep discharge death?
  • Does it seem silly to have a 12 or 24 volt battery powered UPS powering a 12 or 24 volt power supply?
  • Upon loss of DC power from your power supply, the BVUPS™ "bumplessly" transfers your load to battery current. If the duration of the power failure drains the battery to its Use EndVoltage(UEV), it will disconnect the load from the battery to protect the battery from damage due to deep discharge stress.
  • Upon restoration of power, the BVUPS™ recharges your batteries at a controlled rate with power supplied by your regulated power supply. It then maintains your batteries in a fully charged state.
  • With the Power Fail (PF) option the BVUPS™ with  can sense the use of battery current to conditionally close a set of contacts indicating that the system is on battery power. As the battery runs down, the battery power is disconnected and the contacts remain closed (NC). 

The BVUPS12PFA replaces the BVUPS12PF

Also see the battery applications on line hand book and BVUPS FAQ

See Appropriate socket to use with the BVUPS .

See The full line of BVUPS units .

See Power supplies to use with the BVUPS

See Batteries to use with the BVUPS

Specifications

Maximum ratings
Input voltage 30 Vdc
Load current10 amperes at 14 Vdc
Contact Ratings (battery and power fail) Conservatively rated for 10 amps resistive at 240 Vac or 28 Vdc
Dielectric strength 1000 Vac, 60 Hz for one second
Physical
Ambient Operating Temperature 0 C to 60 C
Octal Case Size2.75 X 1.75 X 2.375 inches (excluding octal pins)
Electrical
Protection Diode protected for reverse and over voltage conditions
Power consumption500 milliwatts MAX
24 mA @ 13.6 Vdc
17 mA @ 10.0 Vdc
Supplied voltage10-14 (20-28) VDC (your equipment must be able to operate in these ranges. Most 12 volt equipment is designed to work from 9 to 15 V)
Drop out threshold 10 V +/-200 mV (20V +/-500 mV)
Drop out delay 10 seconds of continuous low voltage
Initial charge rate 1.5 A (Can be programmed to higher values with external charge rate module)
Power fail minimum current 400 mA
(Special -10 125mA versions available)

New! Compatible Din Rail power supplies

Product Link BVUPS12